Measurement Parameters
LH-900: pH electrode, conductivity electrode, DO electrode and temperature probe
General Features
• Automatic temperature compensation ensures accurate readings over the entire range
• Auto-Read function senses and locks the measurement endpoint
• Calibration due alarm prompts user to calibrate the meter regularly
• Setup menu allows setting the number of calibration points,resolution,stability criteria, temperature unit, date and time, etc.
• Reset function automatically resumes all settings back to the factory defaults• Expanded memory stores or recalls up to 500 data sets
• USB communication interface for data transfer and timed interval readings
pH
• Multiparameter water quality meter is equipped with a 6.5 inches backlit LCD display• 1 to 5 points calibration with automatic recognition for USA, NIST and DIN buffers• Automatic electrode diagnosis shows the pH slope and offset
Conductivity/TDS/Salinity/Resistivity
• 1 to 5 points calibration with automatic recognition for conductivity standards• Selectable cell constant, reference temperature, TDS factor, linear and pure water compensations, seawater and practical salinity measurement modes
• Automatic electrode diagnosis shows the calibration points and factors
Dissolved Oxygen
• 1 or 2 points calibration using the air-saturated water or zero oxygen solution• Salinity and barometric pressure compensations eliminate the measurement error
Specifications
Model Bante900 Bante901 Bante902 Bante903
Model |
LH-900 |
pH |
|
Range |
-2.000~20.000pH |
Accuracy |
±0.002pH |
Resolution |
0.001, 0.01, 0.1pH, selectable |
Calibration Points |
1 to 5 points |
pH Buffer Options |
USA, NIST, DIN or custom |
mV |
|
Range |
±1999.9mV |
Accuracy |
±0.2mV |
Resolution |
0.1, 1mV, selectable |
Calibration Points |
1 point |
Measurement Modes |
Relative or absolute mV |
Conductivity |
|
Range |
0.01~20.00mS/cm |
Accuracy |
±0.5% F.S |
Resolution |
0.001, 0.01, 0.1, 1, automatic |
Calibration Points |
1 to 5 points |
Temperature Coefficient |
Linear (0.0~10.0%/°C) or pure water compensation |
Cell Constant |
K=0.1, 1, 10 or custom |
Reference Temperature |
20°C or 25°C |
Dissolved Oxygen |
|
DO Range |
0.00~20.00mg/L |
Accuracy |
±0.2mg/L |
Resolution |
0.01, 0.1mg/L, selectable |
% Saturation of Oxygen |
0.0~200.0% |
Accuracy |
±2.0% |
Resolution |
0.1, 1%, selectable |
Calibration Points |
1 or 2 points |
Pressure Correction |
60.0~112.5kPa, 450~850mmHg, manual |
Salinity Correction |
0~50g/L, manual |
Temperature |
|
Range |
0~105°C, 32~221°F |
Accuracy |
±0.5°C, ±0.9°F |
Resolution |
0.1°C, 0.1°F |
Offset Calibration |
1 point |
Calibration Range |
Measured value ±10°C |
General |
|
Temperature Compensation |
0~100°C, 32~212°F, manual or automatic |
Memory |
Stores up to 500 data sets |
Power |
DC5V, using AC adapter, 220V/50Hz |
Display |
LCD |